Unbonded strand for a floor slab is a prestressing component made from steel strand individually protected by corrosion-inhibiting grease and a plastic sheath. It forms part of an unbonded post-tensioning tendon, which also requires suitable anchorages and related accessories. To select it, buyers should align the strand specification, protection system, and anchorage configuration with the project engineer’s design and applicable requirements. DALU can support B2B buyers by reviewing project specifications and preparing a supply quotation based on the requested configuration.
This guide is intended for contractors, post-tensioning specialists, distributors, engineers, and procurement teams sourcing materials for concrete floor slabs. It focuses on the strand and tendon components that buyers need to define before requesting a quotation. It is not a substitute for structural design or project-specific engineering approval. The final selection should follow the project documents and the requirements of the responsible design professional.
In a post-tensioned slab, tendons are positioned within the formwork before concrete placement and stressed after the concrete reaches the strength specified for stressing. The strand applies prestressing force through the anchorage system, while its grease and sheath allow it to remain unbonded along the tendon length. Unlike a bonded system, the strand is not surrounded by grout intended to bond it to the concrete along its length. Tendon layout, stressing sequence, concrete strength, and anchorage details must be established for the particular structure.
Unbonded tendons are used in a range of post-tensioned concrete floor systems, including commercial buildings, residential structures, parking facilities, and other projects where the design calls for post-tensioning. Whether they suit a particular slab depends on factors such as structural layout, loading, exposure conditions, construction method, and local code requirements. Buyers should provide the intended application and project location when asking for product recommendations or a quotation. The supplier can help clarify product details, but the engineer remains responsible for design suitability.
The core is generally a seven-wire prestressing strand. A typical unbonded tendon protects that strand with a corrosion-inhibiting coating and a continuous extruded plastic sheath, but the specified materials and construction should be confirmed against the project requirements. The sheath helps isolate the strand from the surrounding concrete, while the coating provides an additional protective layer. Buyers should request clear product descriptions and confirm how the supplied product is packaged and identified.
Available strand diameters and strength grades vary by specification and market. For initial comparison, 12.7 mm and 15.2 mm are commonly encountered nominal strand diameter options, and 1,860 MPa is a commonly specified nominal tensile strength for prestressing strand. These are reference points, not a recommendation or guarantee that a given configuration meets a project’s requirements. Confirm the required diameter, grade, tolerance, and governing standard in the procurement documents before placing an order.
Each tendon system also needs compatible anchorage components, which transfer the prestressing force to the concrete at the tendon ends. Depending on the project and system, the procurement scope may include wedges, anchor heads, bearing plates, caps, or other specified accessories. Components should be checked as a coordinated system rather than selected independently based only on strand diameter. Ask the supplier to state exactly which items are included in the quotation and which must be sourced separately.
If you want to learn more, please visit our website DALU.
Pricing for unbonded strand depends on the specified strand configuration, coating and sheath requirements, accessories, order quantity, packaging, and delivery destination. A meaningful comparison requires quotations based on the same scope; a strand-only price should not be compared directly with a complete tendon package. Minimum order quantities and production or shipping schedules depend on the supplier’s current capacity and the requested configuration. DALU can confirm these details after reviewing the buyer’s specification and delivery plan.
For a faster and more accurate quotation, include the strand diameter and grade, standard or technical specification, estimated quantity, accessory scope, destination, and target delivery date. Attach drawings or a bill of materials when available, while identifying which documents are for reference and which contain approved requirements. If final quantities are not confirmed, label them as estimates so that the supplier can distinguish budget pricing from a firm order. Ask the supplier to state any assumptions or exclusions in writing.
These questions help buyers compare suppliers on more than unit price. They also make it easier to identify scope gaps before procurement and reduce avoidable clarification during order processing. Do not treat a supplier’s product description as engineering approval or as proof of compliance unless the required documentation has been reviewed. Record agreed specifications and deviations in the purchase documents.
A frequent mistake is ordering strand without confirming whether the project requires complete tendons or separate anchorage components. Another is specifying only a diameter while leaving grade, protection, standard, or documentation requirements undefined. Buyers can also create delays by submitting inconsistent quantities or by changing delivery requirements after a quotation is prepared. A complete, internally consistent inquiry gives suppliers a better basis for pricing and fulfillment.
Do not select a product solely because it was used on a different project. Design loads, slab geometry, exposure, construction sequence, and local requirements can differ substantially from one job to another. If a substitution is being considered, obtain formal review and approval from the responsible engineer before procurement. Keep the approved design basis and the supplier’s confirmed product details available to the installation team.
For floor-slab applications, an unbonded strand is only one part of a post-tensioning tendon system: strand, protective coating and sheath, and compatible anchorages must be considered together. Begin with the approved project specification, confirm the complete supply scope, and compare suppliers using consistent technical and commercial requirements. The reference sizes and strength grade in this guide are common examples, not a substitute for project-specific selection. The engineer’s approved documents should determine the final product requirements.
To request a DALU quotation, send your project specification, estimated quantity, required accessories, delivery destination, and target schedule. If you have drawings or a bill of materials, include them and identify any open technical questions. DALU can review the inquiry, clarify the proposed supply scope, and provide pricing and availability for the requested configuration. This gives your procurement team a practical starting point for evaluating unbonded strand for a floor slab.
For more information, please visit Unbonded Strand For Floor Slab.