Unbonded post tensioning strand is a high-strength steel tendon strand individually coated with corrosion-inhibiting grease and enclosed in a protective plastic sheath. This arrangement allows the strand to move relative to the surrounding concrete as it is stressed, rather than bonding along its length. To select the right product, confirm the strand diameter and strength, the grease and sheathing requirements, project specifications, packaging, and the supplier’s quality documentation. Common nominal strand diameters include 12.7 mm and 15.2 mm, and 1860 MPa is a commonly specified tensile strength; these are reference options, not universal requirements.
For more information, please visit our website.
This guide is intended for contractors, post-tensioning system providers, distributors, engineers, and procurement teams sourcing unbonded post tensioning strand. It is especially useful when comparing quotations, preparing a technical inquiry, or checking whether a proposed product aligns with a project specification. Final selection and tendon design should be confirmed by the responsible project engineer and the relevant post-tensioning system requirements. This article provides purchasing guidance and does not replace structural design or installation procedures.
The strand is commonly made from multiple high-strength steel wires twisted together, with seven-wire strand being a familiar construction in post-tensioning applications. For an unbonded tendon, the strand is coated with grease and enclosed in a polymer sheath, which separates it from the concrete. After concrete placement and curing to the design requirements, the tendon is stressed using specified equipment and anchored at its ends. The design and installation documents define the required stressing sequence, force, elongation checks, anchorage details, and acceptance criteria.
Unbonded post-tensioning is used in a range of concrete construction, including building floors and slabs, parking structures, and some foundation or transfer elements. Its suitability depends on the structural design, exposure conditions, local codes, and the selected post-tensioning system. A product that works for one project may not meet another project’s requirements, even when the strand diameter is the same. Buyers should provide the intended application and project specification when requesting a quotation.
Start by checking the parameters that affect compatibility with the design and tendon system. The project specification should take priority over generic product descriptions or assumptions based on a previous order. We recommend documenting each requirement in the inquiry so that the supplier can identify discrepancies before production or dispatch.
| Parameter | What to confirm | Why it matters |
|---|---|---|
| Nominal strand diameter | For example, 12.7 mm or 15.2 mm, as specified | Must match the design, anchorage components, and system documentation. |
| Tensile strength grade | For example, 1860 MPa where the project requires it | Strength requirements affect design assumptions and product acceptance. |
| Applicable standard | Standard name, edition, and any project-specific clauses | Clarifies material, testing, marking, and documentation expectations. |
| Grease and sheath | Required material characteristics, coverage, and dimensions | These components protect and separate the strand in the specified system. |
| Packaging and identification | Coil or bundle format, labels, and traceability information | Supports receiving inspection, storage, and order management. |
The values above are examples of commonly encountered specifications, not a complete product standard or a substitute for the project documents. Diameter and strength designations should be checked against the applicable standard and system configuration, since terminology and acceptance requirements can vary. Ask for the supplier’s technical data and inspection documents for the exact item quoted. Do not assume that two products are interchangeable based on nominal diameter alone.
First, identify the governing drawings, specifications, codes, and post-tensioning system requirements. Extract the required strand size, grade, coating and sheath details, acceptable tolerances, and documentation requirements. Then check that the anchorage system and installation method specified for the project are compatible with the proposed tendon product. If documents conflict or omit a requirement, raise the question with the engineer or system provider before placing an order.
If you are looking for more details, kindly visit DALU.
Exposure conditions can affect the protection requirements stated for a project, so buyers should confirm the specified corrosion protection rather than select a coating by assumption. Storage and transport matter as well: damaged sheath, contamination, or poor handling can create inspection and installation concerns. Confirm how the product will be packed, identified, and protected during shipping, and define the receiving checks with the installation team. Any repair or acceptance decision should follow the project’s approved procedures.
Price comparisons should account for the complete supply scope, not just a price per unit of strand. Grease and sheath configuration, packing, inspection documentation, order volume, and destination can influence a quotation. Minimum order quantities and lead times vary by supplier, product configuration, and current production schedule, so request written confirmation rather than relying on general estimates. For time-sensitive projects, provide the required delivery date and ask the supplier to identify schedule assumptions or constraints.
A capable supplier should be able to clarify the offered configuration and identify requirements that need confirmation; buyers should still evaluate the evidence supplied against their own project criteria. Avoid relying on broad claims such as “suitable for all projects” without checking the technical details. Where the purchasing specification is incomplete, ask for a documented clarification before approving the order. Keeping the approved quotation, technical documents, and purchase order aligned reduces the risk of receiving a different configuration than intended.
One frequent mistake is choosing by diameter alone, without confirming the strength grade, standard, and tendon-system compatibility. Another is treating grease and sheath as interchangeable details rather than specified parts of the unbonded tendon assembly. Buyers may also underestimate documentation and shipping requirements, particularly when products cross borders or deliveries are split across phases. To reduce these risks, issue a complete specification and obtain written confirmation of every material and logistical requirement before production begins.
At DALU, we support B2B inquiries for unbonded post tensioning strand by reviewing the requested product details and clarifying the information needed to prepare a suitable quotation. Send us the project’s strand diameter, strength grade, applicable standard, grease and sheath requirements, estimated quantity, destination, and target delivery date. If available, include relevant specification pages or a material schedule so that we can compare the inquiry with the requested configuration. Final approval should remain with the buyer’s engineering or post-tensioning system team.
The right unbonded post tensioning strand is the one that matches the project design, applicable specifications, and approved tendon system—not simply the most familiar size or the lowest quotation. Confirm the strand’s diameter and grade, protection details, documentation, packaging, and delivery conditions before purchasing. As practical reference points, projects may specify 12.7 mm or 15.2 mm strand and a 1860 MPa strength grade, but the governing documents must determine the actual selection. Share those requirements with DALU to start a focused technical and commercial inquiry.
Are you interested in learning more about Unbonded Post Tensioning Strand? Contact us today to secure an expert consultation!