How to Stop Glue Stringing in Automatic Dispensing

25, Nov. 2026

 

How to Stop Glue Stringing in Automatic Dispensing

To stop glue stringing in automatic dispensing, identify whether the cause is the adhesive, the dispensing settings, or the nozzle and shutoff action. Start by checking the material’s temperature and condition, then reduce pressure or flow slightly, improve the valve’s suck-back or cutoff, and check nozzle clearance and retraction. Change one variable at a time and test on a representative part; do not exceed the adhesive or equipment manufacturer’s operating limits.

View Details

At SONGNA, we recommend treating stringing as a process-control issue rather than immediately replacing the dispenser. This is especially important when applying small adhesive deposits near loose diamonds or other delicate components, where excess material can affect appearance, contaminate a setting, or require rework. The right fix depends on the adhesive and the valve, so a controlled trial is more dependable than a universal setting.

Quick Summary: What to Check First

  • Confirm the adhesive is within its specified storage, working, and temperature conditions.
  • Check for excessive pressure, flow, dispense time, or a slow valve cutoff.
  • Inspect the nozzle for residue, damage, or a size that does not suit the deposit.
  • Review nozzle height and motion settings, including retraction and travel speed.
  • Run a small, documented trial, changing one setting at a time.

Why Glue Strings Form During Automatic Dispensing

A glue string forms when adhesive continues to stretch between the nozzle and the workpiece as the dispenser moves away. Some adhesives are more prone to this behavior because of their viscosity, elasticity, formulation, or temperature. The equipment can contribute too: pressure may continue pushing material after the dispense command, or the valve may not close cleanly.

Stringing can also result from a mismatch between the material and process. A very small deposit, a fine nozzle, a high dispensing rate, or a long travel path may make cutoff more difficult, depending on the adhesive and valve design. For precision work around loose diamonds, test the process on a sample or suitable fixture before applying changes to valuable components.

Step-by-Step Troubleshooting Process

1. Check the adhesive and its condition

Read the adhesive supplier’s instructions for storage, shelf life, mixing, working time, and allowable temperature range. Check whether the material is expired, contaminated, improperly mixed, or showing signs of separation. If it is supplied in a cartridge or syringe, confirm that the container and feed path are suitable for the material and dispensing system.

Do not raise the material temperature simply to make it flow more easily. Heat can change viscosity and working time, and some formulations may be sensitive to temperature. If temperature adjustment is permitted, stay within the manufacturer’s stated range and make a small, recorded change; a 2–5°C trial is only appropriate when that range allows it.

2. Reduce excess flow and pressure carefully

Excessive pressure or dispense time can leave a larger bead than needed, which gives the adhesive more material to stretch into a tail. Reduce pressure or flow in small increments while checking whether the deposit still meets the application requirement. A 10–20% reduction can be used as an initial trial range only if the machine’s controls allow it and the adhesive continues to dispense reliably.

Also review dispense duration and any pauses at the end of the cycle. A long dwell may add material or allow adhesive to creep, depending on the valve and formulation. Record the original setting before making changes so you can return to a known baseline.

3. Improve cutoff and suck-back behavior

For a valve with suck-back or vacuum control, check whether the feature is enabled and configured for the material. Increase suck-back gradually rather than applying a large correction at once; excessive negative pressure can draw air into the material or disrupt the next deposit. If the system uses a mechanical shutoff, verify that the valve closes promptly and consistently.

Not every dispenser has the same cutoff mechanism or adjustment range. Consult the machine and valve documentation before changing timing, vacuum, or closing speed. If the tail remains despite reasonable settings, the valve type or material may be a poor match for the required deposit.

For more information, please visit SONGNA.

4. Inspect the nozzle and dispensing path

Look for dried adhesive, buildup, a bent tip, or an inconsistent opening. Residue around the outlet can pull material outward after shutoff, while a nozzle that is too large can produce an oversized deposit. Clean or replace the nozzle using the adhesive and equipment supplier’s recommended procedure, and confirm that the selected tip is compatible with the material.

Check the full path from container to nozzle as well. Trapped air, loose connections, or material left in an unsuitable line may cause inconsistent flow. Follow the equipment maker’s purging and maintenance guidance; do not use an unapproved solvent or cleaning method that could damage seals or contaminate the adhesive.

5. Adjust nozzle position and movement

A nozzle positioned too far from the surface can leave a longer strand as it retracts. If the part geometry permits, test a closer approach and a controlled lift after cutoff, while preserving safe clearance from the component. A 0.5–1 mm adjustment may be a useful trial on some setups, but it is not a universal target: the correct distance depends on the nozzle, deposit, fixture, and workpiece.

Review the motion sequence as well as the dispense command. A brief pause after shutoff, a faster initial retraction, or a different travel path may help some material-and-valve combinations, but can worsen others. Keep the nozzle clear of loose diamonds and settings, and verify the revised motion under the actual cycle conditions.

Use a Controlled Trial to Find the Cause

Before tuning, produce a baseline sample and record the adhesive lot, nozzle type, pressure, dispense time, temperature, and motion settings. Change only one variable per trial so that you can tell which adjustment affected the string. Inspect both the deposited spot and the area around it, since a shorter tail is not a useful improvement if the deposit becomes incomplete or misplaced.

For small or high-value parts, test on a representative sample, dummy setting, or process coupon first. Check repeatability across multiple dispense cycles rather than relying on one successful shot. If the problem varies from cycle to cycle, investigate material consistency, air in the feed, valve timing, or maintenance before making more aggressive setting changes.

Common Mistakes to Avoid

  • Changing several settings at once: This makes it difficult to identify the effective correction.
  • Increasing heat without checking material guidance: Temperature changes can affect more than viscosity.
  • Using excessive suck-back: Too much retraction may introduce air or make the next deposit unstable.
  • Choosing a nozzle by diameter alone: Material behavior, deposit size, and valve design also matter.
  • Testing directly on valuable work: Validate adjustments on a representative sample first.
  • Ignoring maintenance: A setting change will not reliably correct a clogged or damaged nozzle.

When to Review the Dispensing Equipment

If stringing continues after the adhesive, nozzle, settings, and motion sequence have been checked, review whether the dispenser is suitable for the material and required deposit. Consider the adhesive’s viscosity and working behavior, the required shot size, the production cycle, and the precision needed around the component. A system that dispenses consistently with one material may not deliver the same cutoff with another.

For jewelry or loose-diamond applications, discuss the process as a complete setup rather than specifying a machine in isolation. Share the adhesive type or its available technical information, target deposit, workpiece geometry, desired cycle, and current symptoms with your equipment supplier. This gives the supplier a more useful basis for reviewing valve options, control functions, nozzle selection, and process trials without assuming a particular configuration will solve every case.

Conclusion: Stop Stringing with Measured Adjustments

The practical way to stop glue stringing in automatic dispensing is to find where the adhesive keeps flowing or stretching, then correct that cause with controlled changes. Check the material first, reduce excess output if appropriate, verify cutoff and suck-back, inspect the nozzle, and optimize the nozzle’s position and movement. Keep every adjustment within the equipment and adhesive manufacturer’s limits, and confirm results on a representative sample.

If your current process still produces tails or inconsistent deposits, prepare a short record of the material, nozzle, settings, and test results before requesting supplier support. SONGNA can discuss your dispensing requirements and help you evaluate suitable equipment or process adjustments for your application. Contact our team with your target deposit and operating conditions to start a practical technical review.

The company is the world’s best How to Stop Glue Stringing in Automatic Dispensing supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.